DET. DE DUCTO INNOVAFLEX 4 HILOS 24VAC/DC, 120VAC INCLUYE DET 2D51A

MI-D4120

Description

DETECTOR DE HUMO DE DUCTOS 4 HILOS INNOVAIRFLEX 24VAC/DC, 120VAC INCLUYE DET 2D51A
InnovairFlex 4-wire Photoelectric Duct Smoke Detector w/ Low-flow Technology, 24VAC/DC, 120VAC. Includes 2D51A detector
Marca: MIRCOM
Modelo: D4120

Detector de humo de conductos fotoeléctricos de 4 hilos InnovairFlex / Tecnología de bajo flujo, 24 VCA / DC, 120 VCA Incluye detector 2D51A.

Description
Features
• Photoelectric, integrated low-flow technology
• Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
• Versatile mounting options in square or rectangular configuration with modular construction
• Plug-in sensor offers superb false alarm immunity and the latest sensor technology
• Broad ranges for operating temperature (-4oF to 158oF) and humidity (0% to 95% non-condensing)
• Patented sampling tube installs from front or back of the detector with no tools required
• Increased wiring space with a newly added 3⁄4 inch conduit knockout
• One easy-access Test/Reset button and improved LED status
• Patented interconnect feature for multi-fan shutdown
• New high contrast terminal designations
• Built-in short circuit protection from operator wiring errors
• Field selectable settings for configuring the detector
• Two DPDT Form-C relay contacts
• 24 VAC/DC or 120 VAC
• Backward compatibility with existing Innovair products, including remote accessories
Architectural/Engineering Specifications
The air duct smoke detector shall be a System Sensor InnovairFlexTM D4120(A) Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A or ULC listed specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4000 ft/min (0.5 m/ sec to 20.32 m/sec). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch or remote testing using the RTS451KEY(A) remote test station. Terminal connections shall be of the strip and clamp method suitable for 12–18 AWG wiring.
APPROVED
The InnovairFlex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of –4°F to 158°F, and a humidity range of 0to95percent(non-condensing). Aplug-insensorheadoffers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance.
The InnovairFlex housing provides ample wiring space, a 3⁄4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source.
An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED statu